Schema reference / Tables / view MDX source
hand_grip_strength
The maximum voluntary isometric force generated by the muscles of the hand and forearm during a gripping action, usually measured with a hand-held dynamometer.
The maximum voluntary isometric force generated by the muscles of the hand and forearm during a gripping action, usually measured with a hand-held dynamometer.
Purpose. To record the measured handgrip strength of an individual, typically using a hand dynamometer.
Source
| Model | Leg | Role |
|---|---|---|
openEHR-EHR-OBSERVATION.hand_grip_strength.v1 | openEHR | defines this table |
Columns
| Column | Type | Null | Description | Source |
|---|---|---|---|---|
id | uuid primary key | no | Primary key. | — |
form_id | uuid → form | no | The form this entry was recorded on. | — |
form_block_id | uuid | yes | The block within the form, when the entry is bound to one. | — |
event_type | text | yes | null represents any_event | — |
measured_handmeasured_hand_codemeasured_hand_systemmeasured_hand_valueset_id | coded texttext, text, text, text | yes | Measured hand | /data[at0001]/events[at0002]/data[at0003]/items[at0004] |
grip_strength_magnitudegrip_strength_units | quantitynumeric, text | yes | Grip strength | /data[at0001]/events[at0002]/data[at0003]/items[at0007] |
comment | text | yes | Comment | /data[at0001]/events[at0002]/data[at0003]/items[at0008] |
confounding_factors | text | yes | Confounding factors | /data[at0001]/events[at0002]/state[at0013]/items[at0019] |
measurement_protocolmeasurement_protocol_codemeasurement_protocol_systemmeasurement_protocol_valueset_id | coded texttext, text, text, text | yes | Measurement protocol | /protocol[at0011]/items[at0032] |
grip_span_magnitudegrip_span_units | quantitynumeric, text | yes | Grip span | /protocol[at0011]/items[at0039] |
measuring_device | uuid | yes | Measuring device | /protocol[at0011]/items[at0010] |
Constraints
check ((measured_hand_code is null and measured_hand_system is null and measured_hand_valueset_id is null and measured_hand is null) or (measured_hand is not null and measured_hand_code is not null and measured_hand_system is not null and measured_hand_valueset_id is not null))
check ((grip_strength_magnitude is null and grip_strength_units is null) or (grip_strength_magnitude is not null and grip_strength_units is not null))
check (grip_strength_magnitude is null or (grip_strength_units = 'kgf' and grip_strength_magnitude >= 0) or (grip_strength_units = '[lbf_av]' and grip_strength_magnitude >= 0) or (grip_strength_units = 'N' and grip_strength_magnitude >= 0))
check ((measurement_protocol_code is null and measurement_protocol_system is null and measurement_protocol_valueset_id is null) or (measurement_protocol is not null and measurement_protocol_code is not null and measurement_protocol_system is not null and measurement_protocol_valueset_id is not null))
check ((grip_span_magnitude is null and grip_span_units is null) or (grip_span_magnitude is not null and grip_span_units is not null))
check (grip_span_magnitude is null or (grip_span_units = 'cm' and grip_span_magnitude between 0 and 100) or (grip_span_units = 'mm' and grip_span_magnitude between 0 and 1000))Unique
form_block_id
References
| Columns | Target | On delete |
|---|---|---|
form_id | form | cascade |
form_id, form_block_id | form_block | cascade |
measured_hand_valueset_id, measured_hand_code, measured_hand_system, measured_hand | valueset_code | restrict |
measurement_protocol_valueset_id, measurement_protocol_code, measurement_protocol_system, measurement_protocol | valueset_code | restrict |
measuring_device | device | no action |
Indexes
hand_grip_strength_form_id_idxonform_idhand_grip_strength_measuring_device_idxonmeasuring_device
Value sets
| Value set | Codes |
|---|---|
org.openehr::openEHR-EHR-OBSERVATION.hand_grip_strength.v1/measured_hand | 2 |
org.openehr::openEHR-EHR-OBSERVATION.hand_grip_strength.v1/measurement_protocol | 3 |