timed_25_foot_walk

The Timed 25-Foot Walk is a quantitative test of lower extremity mobility and motor function.

The Timed 25-Foot Walk is a quantitative test of lower extremity mobility and motor function. It is the first component of the Multiple Sclerosis Functional Composite (MSFC), a series of three tests to document the course of Multiple Sclerosis.

Purpose. To record the measurements recorded during a Timed 25-Foot Walk test, normally as part of the Multiple Sclerosis Functional Composite (MSFC) suite of tests.

Source

ModelLegRole
openEHR-EHR-OBSERVATION.timed_25_foot_walk.v1openEHRdefines this table

Columns

ColumnTypeNullDescriptionSource
iduuid primary keynoPrimary key.
form_iduuidformnoThe form this entry was recorded on.
form_block_iduuidyesThe block within the form, when the entry is bound to one.
event_typetextyesnull represents any_event
timeintervalyesTime/data[at0001]/events[at0002]/data[at0003]/items[at0004]
trial_not_completedbooleanyesTrial Not Completed?/data[at0001]/events[at0002]/data[at0003]/items[at0005]
reasons_for_non_completiontextyesReasons For Non-completion/data[at0001]/events[at0002]/data[at0003]/items[at0006]
confounding_factorstextyesConfounding Factors/data[at0001]/events[at0002]/state[at0009]/items[at0010]
unilateral_assistive_device
unilateral_assistive_device_code
unilateral_assistive_device_system
unilateral_assistive_device_valueset_id
coded text
text, text, text, text
yesUnilateral Assistive Device/protocol[at0011]/items[at0012]
bilateral_assistive_device
bilateral_assistive_device_code
bilateral_assistive_device_system
bilateral_assistive_device_valueset_id
coded text
text, text, text, text
yesBilateral Assistive Device/protocol[at0011]/items[at0020]
more_than_two_attemptsbooleanyesMore Than Two Attempts?/protocol[at0011]/items[at0017]
reasons_for_more_than_two_attemptstextyesReasons For More Than Two Attempts/protocol[at0011]/items[at0018]

Constraints

check ((unilateral_assistive_device_code is null and unilateral_assistive_device_system is null and unilateral_assistive_device_valueset_id is null) or (unilateral_assistive_device is not null and unilateral_assistive_device_code is not null and unilateral_assistive_device_system is not null and unilateral_assistive_device_valueset_id is not null))
check ((bilateral_assistive_device_code is null and bilateral_assistive_device_system is null and bilateral_assistive_device_valueset_id is null) or (bilateral_assistive_device is not null and bilateral_assistive_device_code is not null and bilateral_assistive_device_system is not null and bilateral_assistive_device_valueset_id is not null))

Unique

References

ColumnsTargetOn delete
form_idformcascade
form_id, form_block_idform_blockcascade
unilateral_assistive_device_valueset_id, unilateral_assistive_device_code, unilateral_assistive_device_system, unilateral_assistive_devicevalueset_coderestrict
bilateral_assistive_device_valueset_id, bilateral_assistive_device_code, bilateral_assistive_device_system, bilateral_assistive_devicevalueset_coderestrict

Indexes

Value sets

Value setCodes
org.openehr::openEHR-EHR-OBSERVATION.timed_25_foot_walk.v1/bilateral_assistive_device4
org.openehr::openEHR-EHR-OBSERVATION.timed_25_foot_walk.v1/unilateral_assistive_device3